- Products
- |
- Water Temperature Control Units
Water temperature control unitsup to 90°C (194°F)
All Tool-Temp water temperature control units have a maximum temperature of 90°C (194°F). However, they each have different designs depending on the intended application. Temperature control units for water can be divided into four general categories. Details can be found further down this page.
- Open systems – indirect cooling
- Open systems – direct cooling
- Closed systems – indirect cooling
- Closed systems – direct cooling
Temperature range
Water up to 90°C (194°F)
Heating capacity
Up to 144 kW (BTU/hr 491’348) using water
Pump motors
0.25 kW up to 7.5 kW
(0.36 HP up to 10.0 HP)
Flow rates
28 l/min up to 580 l/min
(7.4 gpm up to 153 gpm)
System
Open system with high cooling capacity
Features
- Flow meter and pressure display
- Mold drain and vacuum mode
- Temperature measurement regualtion at the consumer
- Optional interface controller
- Increased cooling capacity thanks to high efficiency heat exchangers
Fields of application
Plastics, Pharmaceutical, Chemical, Rubber, Food, Wood industry
TT-170 L
- Maximum temperature
90°C (194 °F) - Heating capacity
3 kW (10‘236 BTU/hr) - Cooling capacity
30 kW @ 90°C (194 °F) - Cooling system indirect
- Pump capacity 28 l/min (7.4 gpm);
max. 2.8 bar (40.6 psi) - Medium water
Moulds up to 50 kg (110 lbs), rollers up to 80 mm (3.1 inch) Ø, length 300 mm (11.8 inch)
TT-168 E/A I TT-168 H/A
- Maximum temperature
90°C (194°F) - Heating capacity
18 kW (61‘419 BTU/hr) - Cooling capacity
45 kW @ 90°C (194 °F) - Cooling system indirect
- Typ E
Pump capacity 60 l/min (16 gpm);
max. 4.0 bar (58 psi) - Typ H
Pump capacity 60 l/min (16 gpm); max. 7.0 bar (102 psi) - Medium water
Moulds up to 1'800 kg (3'968 lbs)
TT-168 PHE
- Maximum temperature
90°C (194°F) - Heating capacity
12 kW (40‘946 BTU/hr)
18 kW (61‘419 BTU/hr) - Cooling capacity
50 kW @ 90°C (194°F) indirect
130 kW @ 90°C (194°F) direct - Cooling system indirect
- Type E
Pump capacity 60 l/min (16 gpm);
max. 4.0 bar (58 psi) - Type H
Pump capacity 60 l/min (16 gpm);
max. 7.0 bar (102 psi) - Medium water
12 kW: Moulds up to 1'200 kg (2'645 lbs) / 18 kW: Moulds up to 1'800 kg (3'968 lbs)
TT-118 K
- Maximum temperature
90°C (194°F) - Heating capacity
18 kW (61‘419 BTU/hr)
27 kW (92‘128 BTU/hr)
36 kW (122837 BTU/hr)
45 kW (153546 BTU/hr) - Cooling capacity
200 kW @ 90°C (194°F) indirect
400 kW @ 90°C (194°F) direct - Cooling system indirect
- Pump capacity 200 l/min (53 gpm);
max. 4.3 bar (62 psi) - Medium water
Roller, plates, double-walled vessels, large consumers
TT-1548 E
- Maximum temperature
90°C (194°F) - Heating capacity
12 kW (40‘946 BTU/hr) - Cooling capacity
5 kW @ 70°C (158°F) - Cooling system air-cooled
- Pump capacity 60 l/min (max 16 gpm);
max. 4.0 bar (58 psi) - Medium water
Rotary table systems, Applications without cooling water
TT-108 E
- Maximum temperature
90°C (194°F) - Heating capacity
6 kW (20‘473 BTU/hr)
12 kW (40‘946 BTU/hr)
18 kW (61‘419 BTU/hr) - Cooling capacity
100 kW @ 90°C (194°F) - Cooling system direct
- Pump capacity 60 l/min (16 gpm);
max. 4.0 bar (58 psi) - Medium water
Moulds, plates
TT-108 K
- Maximum temperature
90°C (194°F) - Heating capacity
18 kW (61‘419 BTU/hr)
27 kW (92‘128 BTU/hr)
36 kW (122‘837 BTU/hr)
45 kW (153‘546 BTU/hr) - Cooling capacity
260 kW @ 90°C (194°F) - Cooling system direct
- Pump capacity 200 l/min (52.8 gpm);
max. 4.3 bar (62 psi) - Medium water
Moulds, plates
TT-1500 W
- Maximum temperature
90°C (194°F) - Heating capacity
48 kW (163‘783 BTU/hr) - Cooling capacity
285 kW @ 80°C (176°F) - Cooling system direct
- Pump capacity 350 l/min (93 gpm);
max. 4.5 bar (65 psi) - Medium water
Rollers, plates, double walled vessels, large consumers
TT-1368 W
- Maximum temperature
90°C (194°C) - Heating capacity
24 kW (81‘891 BTU/hr)
48 kW (163‘783 BTU/hr)
72 kW (245‘674 BTU/hr)
96 kW (327‘565 BTU/hr) - Cooling capacity
400 kW @ 70°C (158°F) - Cooling system indirect
- Pump capacity 250 l/min (93 gpm)
max. 4.5 bar (65 psi) - Medium water
Rollers, plates, double-walled vessels, large consumers
TT-1368 V
- Maximum temperature
90°C (194°F) - Heating capacity
72 kW (245‘674 BTU/hr)
96 kW (327‘565 BTU/hr)
144 kW (491‘348 BTU/hr) - Cooling capacity
400 kW @ 80°C (176°F) - Cooling system indirect
- Pump capacity 580 l/min (153 gpm);
max. 4.1 bar (59 psi) - Medium water
Rollers, plates, double-walled vessels, large consumers