1. |
  2. Products
  3. |
  4. Water Temperature Control Units
  5. |
  6. TT-168 E/A I TT-168 H/A

Metric

Water Units

Powerful device with high functionalityTT-168 E/A & TT-168 H/A

Moulds up to 1'800 kg

Summary

  • Maximum temperature 90°C
  • Medium water
  • Heating capacity 18 kW
  • Cooling capacity 45 kW @ 90°C
  • Cooling system indirect
  • Typ E: Pump capacity 60 l/min; max. 4.0 bar
  • Typ H: Pump capacity 60 l/min; max. 7.0 bar

Functions

  • Self-optimizing temperature controller with temperature display
    1/10°C – steps
  • Display in °C to °F and l/min or gal/min
  • Digital flow display and monitoring
  • Automatic temperature control
  • Switchover for temperature control on the mould
  • Heating switchable in stages
  • Pressure display
  • Automatic or manual refill
  • Time limited water refill
  • Automatic mould drainage
  • Leakstopper device – operation in pressure and vacuum mode possible

Construction

  • Submersible sealless pump made from bronze
  • Limescale free heat exchanger
  • Corrosion resistant device for a long service life
  • All parts in contact with water are made of stainless steel or bronze
  • Unit on castors

Safety features

  • Level control for dry run protection
  • Electronic temperature limitation and monitoring in the controller
  • Visual and acoustic fault indications
  • Integrated circuit breakers
  • Main switch, transformer and motor protection switch

Cooling capacity

Pump capacity

Product informationsTT-168 E/A & TT-168 H/A

ProductTT-TT-168 E/A I H/A - 18 kW
Temperature range°C90
Heat transfer mediumwater
   Filling amount max.l20
Heating capacitykW18
Cooling systemindirect
   tubular heat exchangerkW45
   Plate heat exchangerkW
   DirectkW
   At flow temperature°C90
Pump system see diagram
   Typ L: 19 l/min; max. 2.9 bar; motor 0.27 kW
   Typ E: 60 l/min; max. 4.0 bar; motor 0.75 kW
   Typ H: 60 l/min; max. 7.0 bar; motor 1.50 kW
   Typ K: 200 l/min; max. 4.3 bar; motor 2.2 kW
   Typ W: 250-350 l/min; max. 4.5 bar; motor 4.0 kW
   Typ V: 580 l/min; max. 4.1 bar; motor 7.5 kW
   Suction capacity vakuummWS8
ControllerMP-888
   Measurement typeFeKo Typ J
Connections
   Medium1/2" BS
   Cooling water3/8" BS
   Compressed air-
Dimensions incl. castors, LxWxHmm710x325x785
Weight empty approx.kg67
Coloursilvergrey RAL 7001
 
Functions● standard/ ○ optional / - not possible
Flow control
Leakstopper device
Mould drain
Temperature control at the consumer
Time limited water refill
Interface controller
Automatic refill
Level control
Visual fault indications
Acoustic warning
Pressure regulation-

Imperial

Water Units

Powerful device with high functionalityTT-168 E/A & TT-168 H/A

Moulds up to 3'968 lbs

Summary

  • Maximum temperature 194°F
  • Medium water
  • Heating capacity 61‘419 BTU / hr
  • Cooling capacity 45 kW @ 194 °F
  • Cooling system indirect
  • Typ E: Pump capacity 16 gpm; max. 58 psi
  • Typ H: Pump capacity 16 gpm; max. 102 psi

Functions

  • Self-optimizing temperature controller with temperature display
    1/10°F – steps
  • Display in °C to °F and l/min or gal/min
  • Digital flow display and monitoring
  • Automatic temperature control
  • Switchover for temperature control on the mould
  • Heating switchable in stages
  • Pressure display
  • Automatic or manual refill
  • Time limited water refill
  • Automatic mould drainage
  • Leakstopper device – operation in pressure and vacuum mode possible

Construction

  • Submersible sealless pump made from bronze
  • Limescale free heat exchanger
  • Corrosion resistant device for a long service life
  • All parts in contact with water are made of stainless steel or bronze
  • Unit on castors

Safety features

  • Level control for dry run protection
  • Electronic temperature limitation and monitoring in the controller
  • Visual and acoustic fault indications
  • Integrated circuit breakers
  • Main switch, transformer and motor protection switch

Cooling capacity

Pump capacity

Product informationsTT-168 E/A & TT-168 H/A

ProductTT-TT-168 E/A I H/A - 18 kW
Temperature range°F194
Heat transfer mediumwater
   Filling amount max.gal.5.3
Heating capacityBTU/hr61'419
Cooling systemindirect
   tubular heat exchangerkW45
   Plate heat exchangerkW
   DirectkW
   At flow temperature°F194
Pump system see diagram
   Typ L: 5 gpm; max. 42 psi; motor 0.36 HP
   Typ E: 16 gpm; max. 58 psi; motor 1 HP
   Typ H: 16 gpm; max. 102 psi; motor 2 HP
   Typ K: 53 gpm; max. 62 psi; motor 3 HP
   Typ W: 66-93 pgm; max. 65 psi; motor 5.4 HP
   Typ V: 153 gpm; max. 59 psi; motor 10 HP
   Suction capacity vakuuminHg23.17
ControllerMP-888
   Measurement typeFeKo Typ J
Connections
   Medium1/2" NPT
   Cooling water3/8" NPT
   Compressed air-
Dimensions incl. castors, LxWxHinch28×12.8×30.9
Weight empty approx.lbs148
Coloursilvergrey RAL 7001
 
Functions● standard/ ○ optional / - not possible
Flow control
Leakstopper device
Mould drain
Temperature control at the consumer
Time limited water refill
Interface controller
Automatic refill
Level control
Visual fault indications
Acoustic warning
Pressure regulation-