- Products
- |
- Water Temperature Control Units
- |
- TT-1548 E
Metric
Air-cooled temperature control systemTT-1548 E
Rotary table systems, applications without cooling water
Summary
- Maximum temperature 90°C
- Medium water
- Heating capacity 12 kW
- Cooling capacity 5 kW @ 70°C
- Cooling system air-cooled
- Pump capacity 60 l/min; max. 4.0 bar
Functions
- Self-optimizing temperature controller with temperature display
1/10°C – steps - Display in °C to or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Switchover for temperature control on the mould
- Heating switchable in stages
- Automatic mould drainage
- Leakstopper device – operation in pressure and vacuum mode possible
Construction
- Submersible sealless pump made of bronze
- Limescale free heat exchanger
- Corrosion resistant device for a long service life
- All parts in contact with water are made of stainless steel or bronze
- Unit on castors
Safety features
- Level control for dry run protection
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-1548 E
Product | TT-1548 E | ||||
---|---|---|---|---|---|
Temperature range | °C | 90 | |||
Heat transfer medium | water | ||||
Filling amount max. | l | 20 | |||
Heating capacity | kW | 12 | |||
Cooling system | air-cooled | ||||
tubular heat exchanger | kW | 5 | |||
Plate heat exchanger | kW | ||||
Direct | kW | ||||
At flow temperature | °C | 70 | |||
Pump system see diagram | |||||
Typ L: 19 l/min; max. 2.9 bar; motor 0.27 kW | |||||
Typ E: 60 l/min; max. 4.0 bar; motor 0.75 kW | ⚫ | ||||
Typ H: 60 l/min; max. 7.0 bar; motor 1.50 kW | |||||
Typ K: 200 l/min; max. 4.3 bar; motor 2.2 kW | |||||
Typ W: 250-350 l/min; max. 4.5 bar; motor 4.0 kW | |||||
Typ V: 580 l/min; max. 4.1 bar; motor 7.5 kW | |||||
Suction capacity vakuum | mWS | 8 | |||
Controller | MP-888 | ||||
Measurement type | FeKo Typ J | ||||
Connections | |||||
Medium | 3/4" BS | ||||
Cooling water | |||||
Compressed air | - | ||||
Dimensions incl. castors, LxWxH | mm | 870x360x915 | |||
Weight empty approx. | kg | 95 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | ⚫ | ||||
Mould drain | ⚫ | ||||
Temperature control at the consumer | ⚫ | ||||
Time limited water refill | - | ||||
Interface controller | ◯ | ||||
Automatic refill | - | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | - |
Imperial
Air-cooled temperature control systemTT-1548 E
Rotary table systems, applications without cooling water
Summary
- Maximum temperature 194°F
- Medium water
- Heating capacity 40‘946 BTU/hr
- Cooling capacity 5 kW @ 158°F
- Cooling system air-cooled
- Pump capacity 16 gpm; max. 58 psi
Functions
- Self-optimizing temperature controller with temperature display
1/10°F – steps - Display in °C to or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Switchover for temperature control on the mould
- Heating switchable in stages
- Automatic mould drainage
- Leakstopper device – operation in pressure and vacuum mode possible
Construction
- Submersible sealless pump made from bronze
- Limescale free heat exchanger
- Corrosion resistant device for a long service life
- All parts in contact with water are made of stainless steel or bronze
- Unit on castors
Safety features
- Level control for dry run protection
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-1548 E
Product | TT-1548 E | ||||
---|---|---|---|---|---|
Temperature range | °F | 194 | |||
Heat transfer medium | water | ||||
Filling amount max. | gal. | 5.3 | |||
Heating capacity | BTU/hr | 40'946 | |||
Cooling system | air-cooled | ||||
tubular heat exchanger | kW | 5 | |||
Plate heat exchanger | kW | ||||
Direct | kW | ||||
At flow temperature | °F | 158 | |||
Pump system see diagram | |||||
Typ L: 5 gpm; max. 42 psi; motor 0.36 HP | |||||
Typ E: 16 gpm; max. 58 psi; motor 1 HP | ⚫ | ||||
Typ H: 16 gpm; max. 102 psi; motor 2 HP | |||||
Typ K: 53 gpm; max. 62 psi; motor 3 HP | |||||
Typ W: 66-93 pgm; max. 65 psi; motor 5.4 HP | |||||
Typ V: 153 gpm; max. 59 psi; motor 10 HP | |||||
Suction capacity vakuum | inHg | 23.17 | |||
Controller | MP-888 | ||||
Measurement type | FeKo Typ J | ||||
Connections | |||||
Medium | 3/4" NPT | ||||
Cooling water | |||||
Compressed air | - | ||||
Dimensions incl. castors, LxWxH | inch | 34.3x14.2x36 | |||
Weight empty approx. | lbs | 209 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | ⚫ | ||||
Mould drain | ⚫ | ||||
Temperature control at the consumer | ⚫ | ||||
Time limited water refill | - | ||||
Interface controller | ◯ | ||||
Automatic refill | - | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | - |