- Products
- |
- Oil Temperature Control Units
- |
- TT-508 X
Metric
Heating and cooling devicefor large consumersTT-508 X
Rollers, plates, large consumers
Eckdaten
- Maximum temperature 300°C
- Medium oil
- Heating capacity 24 kW | 48 kW
- Cooling capacity 480 kW @ see diagram
- Cooling system indirect
- Pump capacity 260 l/min; max. 4.0 bar
Functions
- Self-optimizing temperature controller with temperature display
1/10°C – steps - Display in °C or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Heating switchable in stages
- Heaters with cascade connection
- Pressure display
Construction
- High-performance centrifugal pump
- Hot oil circuit with bypass, which ensures the internal oil circulation when the valves are closed
- Limescale free heat exchanger
- No cracking of the oil thanks to special heating construction
- Expansion tank with drip pan
- Unit on adjustable feet
Safety features
- Level control for dry run protection
- Expansion vessel with safety shut-off in case of overflow
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-508 X
Product | TT-508 X | ||||
---|---|---|---|---|---|
Temperature range | °C | 300 | |||
Heat transfer medium | oil | ||||
Filling amount | l | 75 | |||
Expansion volume | l | 75 | |||
Heating capacity | kW | 48 | |||
Cooling system | indirect | ||||
Tubular heat exchanger | kW | 480 | |||
Plate heat exchanger | kW | ||||
At flow temperature | °C | see diagram | |||
Pump | |||||
Motor | kW | 4 | |||
Pump system see diagram | |||||
Typ Z: axial face sealed 100 l/min; max. 5.5 bar | |||||
Typ A: magnetic drive 100 l/min; max. 5.5 bar | |||||
Typ X: 260 l/min; max. 4.0 bar | ⚫ | ||||
Typ Y: 200-500 l/min; max. 4.0 bar | |||||
Suction capacity vakuum | mWS | - | |||
Controller | MP-888 | ||||
Measurement sensor | FeKo Typ J | ||||
Connections | |||||
Medium | flange DN32 | ||||
Cooling water outlet | 1 1/2" BS | ||||
Cooling water inlet | 1 1/2" BS | ||||
Water-glycol | - | ||||
Compressed air min. | bar | - | |||
Dimensions incl. castors, LxWxH | mm | 1710x790x1540 | |||
Weight empty approx. | kg | 520 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | - | ||||
Mould drain | - | ||||
Temperature regulation at the consumer | - | ||||
Interface controller | ◯ | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | ◯ | ||||
Double circuit version | - |
Imperial
Heating and cooling devicefor large consumersTT-508 X
Rollers, plates, large consumers
Eckdaten
- Maximum temperature 572°F
- Medium oil
- Heating capacity 81‘891 BTU/hr | 163‘782 BTU/hr
- Cooling capacity 480 kW @ see diagram
- Cooling system indirect
- Pump capacity 69 gpm; max. 58 psi
Functions
- Self-optimizing temperature controller with temperature display
1/10°F – steps - Display in °C or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Heating switchable in stages
- Heaters with cascade connection
- Pressure display
Construction
- High-performance centrifugal pump
- Hot oil circuit with bypass, which ensures the internal oil circulation when the valves are closed
- Limescale free heat exchanger
- No cracking of the oil thanks to special heating construction
- Expansion tank with drip pan
- Unit on adjustable feet
Safety features
- Level control for dry run protection
- Expansion vessel with safety shut-off in case of overflow
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-508 X
Product | TT-508 X | ||||
---|---|---|---|---|---|
Temperature range | °F | 572 | |||
Heat transfer medium | oil | ||||
Filling amount | US gal | 19.8 | |||
Expansion volume | US gal | 19.8 | |||
Heating capacity | BTU/hr | 163'783 | |||
Cooling system | indirect | ||||
Tubular heat exchanger | kW | 480 | |||
Plate heat exchanger | kW | ||||
At flow temperature | °F | see diagram | |||
Pump | |||||
Motor | HP | 5.4 | |||
Pump system see diagram | |||||
Typ Z: axial face sealed 26.4 gpm; max. 80 psi | |||||
Typ A: magnetic drive 26.4 gpm; max. 80 psi | |||||
Typ X: 69 gpm; max. 58 psi | ⚫ | ||||
Typ Y: 53-132 gpm; max. 58 psi | |||||
Suction capacity vakuum | inHg | - | |||
Controller | MP-888 | ||||
Measurement sensor | FeKo Typ J | ||||
Connections | |||||
Medium | flange DN32 | ||||
Cooling water outlet | 1 1/2" NPT | ||||
Cooling water inlet | 1 1/2" NPT | ||||
Water-glycol | - | ||||
Compressed air min. | psi | - | |||
Dimensions incl. castors, LxWxH | inch | 67.3x31.1x60.6 | |||
Weight empty approx. | lbs | 1'146 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | - | ||||
Mould drain | - | ||||
Temperature regulation at the consumer | - | ||||
Interface controller | ◯ | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | ◯ | ||||
Double circuit version | - |