Heating and cooling device for large consumersTT-708 Y
Rollers, plates, large consumers
Summary
- Maximum temperature 300°C
- Medium oil
- Heating capacity 72 kW I 120 kW I 144 kW
- Cooling capacity 600 kW @ see diagram °C
- Cooling system indirect
- Pump capacity 200-500 l/min; max. 4.0 bar
Functions
- Self-optimizing temperature controller with temperature display
1/10°C – steps - Display in °C or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Heating switchable in stages
- Heaters with cascade connection
- Pressure display
- With pressure regulation
Construction
- High-performance centrifugal pump
- Hot oil circuit with bypass, which ensures the internal oil circulation when the valves are closed
- Limescale free heat exchanger
- No cracking of the oil thanks to special heating construction
- Expansion tank with drip pan
- Unit on adjustable feet
Safety features
- Level control for dry run protection
- Expansion vessel with safety shut-off in case of overflow
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-708 Y
Product | TT-708 Y | ||||
---|---|---|---|---|---|
Temperature range | °C | 300 | |||
Heat transfer medium | oil | ||||
Filling amount | l | 100 I 200 I 200 | |||
Expansion volume | l | 100 | |||
Heating capacity | kW | 72 I 120 I 144 | |||
Cooling system | indirect | ||||
Tubular heat exchanger | kW | 600 | |||
Plate heat exchanger | kW | ||||
At flow temperature | °C | see diagram | |||
Pump | |||||
Motor | kW | 7.5 | |||
Pump system see diagram | |||||
Typ Z: axial face sealed 100 l/min; max. 5.5 bar | ⚫ | ||||
Typ A: magnetic drive 100 l/min; max. 5.5 bar | |||||
Typ X: 260 l/min; max. 4.0 bar | |||||
Typ Y: 200-500 l/min; max. 4.0 bar | ⚫ | ||||
Suction capacity vakuum | mWS | - | |||
Controller | MP-888 | ||||
Measurement sensor | FeKo Typ J | ||||
Connections | |||||
Medium | flange DN50 | ||||
Cooling water outlet | 1 1/2" BS | ||||
Cooling water inlet | 1 1/2" BS | ||||
Water-glycol | - | ||||
Compressed air min. | bar | - | |||
Dimensions incl. castors, LxWxH | mm | 2150x1300x1950 | |||
Weight empty approx. | kg | 1270 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | - | ||||
Mould drain | - | ||||
Temperature regulation at the consumer | - | ||||
Interface controller | ◯ | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | ⚫ | ||||
Double circuit version | - |
Imperial
Heating and cooling device for large consumersTT-708 Y
Rollers, plates, large consumers
Summary
- Maximum temperature 572°F
- Medium oil
- Heating capacity 245‘674 BTU/hr I 409‘457 BTU/hr I 491‘348 BTU/hr
- Cooling capacity 600 kW @ see diagram °C
- Cooling system indirect
- Pump capacity 53 – 132 gpm; max. 58 psi
Functions
- Self-optimizing temperature controller with temperature display
1/10°F – steps - Display in °C or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Heating switchable in stages
- Heaters with cascade connection
- Pressure display
- With pressure regulation
Construction
- High-performance centrifugal pump
- Hot oil circuit with bypass, which ensures the internal oil circulation when the valves are closed
- Limescale free heat exchanger
- No cracking of the oil thanks to special heating construction
- Expansion tank with drip pan
- Unit on adjustable feet
Safety features
- Level control for dry run protection
- Expansion vessel with safety shut-off in case of overflow
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-708 Y
Product | TT-708 Y | ||||
---|---|---|---|---|---|
Temperature range | °F | 572 | |||
Heat transfer medium | oil | ||||
Filling amount | US gal | 26.4 I 52.8 I 52.8 | |||
Expansion volume | US gal | 26.4 | |||
Heating capacity | BTU/hr | 245'674 I 409'457 I 491'348 | |||
Cooling system | indirect | ||||
Tubular heat exchanger | kW | 600 | |||
Plate heat exchanger | kW | ||||
At flow temperature | °F | see diagram | |||
Pump | |||||
Motor | HP | 10.1 | |||
Pump system see diagram | |||||
Typ Z: axial face sealed 26.4 gpm; max. 80 psi | ⚫ | ||||
Typ A: magnetic drive 26.4 gpm; max. 80 psi | |||||
Typ X: 69 gpm; max. 58 psi | |||||
Typ Y: 53-132 gpm; max. 58 psi | ⚫ | ||||
Suction capacity vakuum | inHg | - | |||
Controller | MP-888 | ||||
Measurement sensor | FeKo Typ J | ||||
Connections | |||||
Medium | flange DN50 | ||||
Cooling water outlet | 1 1/2" NPT | ||||
Cooling water inlet | 1 1/2" NPT | ||||
Water-glycol | - | ||||
Compressed air min. | psi | - | |||
Dimensions incl. castors, LxWxH | inch | 84.7x51.2x76.8 | |||
Weight empty approx. | lbs | 2'800 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | - | ||||
Mould drain | - | ||||
Temperature regulation at the consumer | - | ||||
Interface controller | ◯ | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | ⚫ | ||||
Double circuit version | - |