- |
- Products
- |
- Oil Temperature Control Units
- |
- TT-409 Z
Metric
High performance unit with wide temperature range: -20°C up to +240°CTT-409 Z
Reactors from 50 up to 150 litres
Summary
- Maximum temperature 240°C
- Medium oil
- Heating capacity 24 kW
- Cooling capacity
93 kW @ 230°C indirect
150 kW @ 80°C direct - Cooling system indirect
- Pump capacity with axial face seal 60 l/min; max. 3.5 bar
Functions
- Self-optimizing temperature controller with temperature display
1/10°C – steps - Display in °C or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Switchover for temperature control at the consumer
- Heating switchable in stages
- Heaters with cascade connection
- Pressure indication: pump, compressed air unit, compressed air mains
- With pressure regulation
Construction
- High temperature pump with mechanical seal
- Hot oil circuit with bypass, which ensures the internal oil circulation when the valves are closed
- With two cooling circuits:
circuit 1: +80°C to +240°C
circuit 2: -20°C to +80°C - Limescale free heat exchanger
- No cracking of the oil thanks to special heating construction
- All parts in contact with water are made of stainless steel or bronze
- Unit on castors
Safety features
- Level control for dry run protection
- Expansion vessel with safety shut-off in case of overflow
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-409 Z
Product | TT-409 Z | ||||
---|---|---|---|---|---|
Temperature range | °C | 240 | |||
Heat transfer medium | oil | ||||
Filling amount | l | 60 | |||
Expansion volume | l | 36 | |||
Heating capacity | kW | 24 | |||
Cooling system | indirect | ||||
Tubular heat exchanger | kW | 93 | |||
Plate heat exchanger | kW | 150 | |||
At flow temperature | °C | 230 I 80 | |||
Pump | |||||
Motor | kW | 1.8 | |||
Pump system see diagram | |||||
Typ Z: axial face sealed 100 l/min; max. 5.5 bar | ⚫ | ||||
Typ A: magnetic drive 100 l/min; max. 5.5 bar | |||||
Typ X: 260 l/min; max. 4.0 bar | |||||
Typ Y: 200-500 l/min; max. 4.0 bar | |||||
Suction capacity vakuum | mWS | - | |||
Controller | MP-888 | ||||
Measurement sensor | Pt-100 | ||||
Connections | |||||
Medium | 1" BS | ||||
Cooling water outlet | 3/4" BS | ||||
Cooling water inlet | |||||
Water-glycol | 3/4" BS | ||||
Compressed air min. | bar | 5 | |||
Dimensions incl. castors, LxWxH | mm | 1380x720x1500 | |||
Weight empty approx. | kg | 340 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | - | ||||
Mould drain | - | ||||
Temperature regulation at the consumer | ⚫ | ||||
Interface controller | ◯ | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | ⚫ | ||||
Double circuit version | - |
Imperial
High performance unit with wide temperature range: -4°F up to 464°FTT-409 Z
Reactors from 13.2 up to 39.6 gallons
Summary
- Maximum temperature 464°F
- Medium oil
- Heating capacity 81‘891 BTU/hr
- Cooling capacity
93 kW @ 446°F indirect
150 kW @ 176°F direct - Cooling system indirect
- Pump capacity with axial face seal 26.4 gpm; max. 80 psi
Functions
- Self-optimizing temperature controller with temperature display
1/10°F – steps - Display in °C or °F and l/min or gal/min
- Digital flow display and monitoring
- Automatic temperature control
- Switchover for temperature control at the consumer
- Heating switchable in stages
- Heaters with cascade connection
- Pressure indication: pump, compressed air unit, compressed air mains
- With pressure regulation
Construction
- High temperature pump with mechanical seal
- Hot oil circuit with bypass, which ensures the internal oil circulation when the valves are closed
- With two cooling circuits:
circuit 1: 176°F to 464°F
circuit 2: -4°F to 176°F - Limescale free heat exchanger
- No cracking of the oil thanks to special heating construction
- All parts in contact with water are made of stainless steel or bronze
- Unit on castors
Safety features
- Level control for dry run protection
- Expansion vessel with safety shut-off in case of overflow
- Electronic temperature limitation and monitoring in the controller
- Mechanical safety thermostats
- Visual and acoustic fault indications
- Integrated circuit breakers
- Main switch, transformer and motor protection switch
Product informationsTT-409 Z
Product | TT-409 Z | ||||
---|---|---|---|---|---|
Temperature range | °F | 464 | |||
Heat transfer medium | oil | ||||
Filling amount | US gal | 15.9 | |||
Expansion volume | US gal | 9.5 | |||
Heating capacity | BTU/hr | 81'891 | |||
Cooling system | indirect | ||||
Tubular heat exchanger | kW | 93 | |||
Plate heat exchanger | kW | 150 | |||
At flow temperature | °F | 446 I 176 | |||
Pump | |||||
Motor | HP | 2.4 | |||
Pump system see diagram | |||||
Typ Z: axial face sealed 26.4 gpm; max. 80 psi | ⚫ | ||||
Typ A: magnetic drive 26.4 gpm; max. 80 psi | |||||
Typ X: 69 gpm; max. 58 psi | |||||
Typ Y: 53-132 gpm; max. 58 psi | |||||
Suction capacity vakuum | inHg | - | |||
Controller | MP-888 | ||||
Measurement sensor | Pt-100 | ||||
Connections | |||||
Medium | 1" NPT | ||||
Cooling water outlet | 3/4" NPT | ||||
Cooling water inlet | |||||
Water-glycol | 3/4" NPT | ||||
Compressed air min. | psi | 73 | |||
Dimensions incl. castors, LxWxH | inch | 54.3x28.4x59.1 | |||
Weight empty approx. | lbs | 750 | |||
Colour | silvergrey RAL 7001 | ||||
Functions | ● standard/ ○ optional / - not possible | ||||
Flow control | ⚫ | ||||
Leakstopper device | - | ||||
Mould drain | - | ||||
Temperature regulation at the consumer | ⚫ | ||||
Interface controller | ◯ | ||||
Level control | ⚫ | ||||
Visual fault indications | ⚫ | ||||
Acoustic warning | ⚫ | ||||
Pressure regulation | ⚫ | ||||
Double circuit version | - |